4.8.8. Alarm Notification Using Email
The TRip2 also includes an SMTP client for the purpose of transmitting alarm status messages via
email.
Most parameters of the email message are configurable to allow maximum flexibility, but the
subject and message body of an email sent when an alarm set will be:
Subject: [Unit Name] Trip2 [Alarm Name] alarm set
Body: [Unit Name] The [Alarm Name] has been set on this Trip2 unit
Where [Unit Name] will be replaced with the unit’s configured name (with the unit set name
command) and [Alarm Name] is the name of the alarm either RTP, RTCP or LCP.
The subject and message body of an email sent when an alarm is cleared will be:
Subject: [Unit Name] Trip2 [Alarm Name] alarm cleared
Body: [Unit Name] The [Alarm Name] has been cleared on this Trip2 unit
The use of a suitable email-to-SMS gateway application will allow the signalling of alarm conditions
to mobile telephones via SMS messages.
4.9. Patching
Note: Patching functionality is only available for TRip2 version 1.0.27 and later. Please follow the
TRip2 update procedure if you need to upgrade to a newer version.
The TRip2 can be configured to use a patching mode, which allows two radio sites to enable/disable
talkthrough. This can be triggered by the value of a logic pin or in response to a selcall message at
either site, and patching activation/deactivation can be monitored via a generated selcall message or
a logic output.
When patching is activated, logic packets (containing, for example, COR and PTT logic levels) will be
passed between the TRip2 units as usual, allowing one site’s COR to trigger the other site’s PTT and
vice-versa. When patching is deactivated, logic packets will still be sent as a “keep-alive” measure,
but logic levels will be ignored, meaning a COR at one site no longer triggers PTT at the other.
Although selcall and logic pin monitoring/responses can be used together, the following two sections
describe them independently.
4.9.1. Patching Using Selcall
For patching to be triggered via selcall messages, an “on” and “off” selcall message must be set on
both TRip2 units, and this must be the same for each unit. When the TRip2 units see the selcall “on”
message, patching will be activated. It will then be deactivated when the selcall “off” message is
received. Additionally, a timeout of between 5 and 500 seconds can be set, after which patching will
be deactivated.
The TRip2 units can also be configured to generate selcall strings when patching is activated or
deactivated. The patching deactivated selcall string will be sent whether patching mode has been
deactivated by an incoming “off” message or a timeout.