TRip2 Manual, Version 1.5 Page 16 of 34 © AWCSL 2010
(...)
[TRip2]>> unit set update server aw-comms.com
(...)
[TRip2]>> unit set update file downloads/trip2-updates/update-
x.y.z.tar.bz2
Update Protocol: http
Update Server: aw-comms.com
Update File: downloads/trip2-updates/update-x.y.z.tar.bz2
[Trip2]>> unit update now
trip2-updater: Starting
(...)
Restarting software...
The update procedure will continue even if the telnet/SSH session with the unit is terminated. In this
case the unit can be logged into later and the version number checked to see if the update was
successful. While the update is happening, anyone logging into the TRip2 unit can see the update
progress message as they are printed by issuing the command “unit update notify”.
When the update is complete, the unit’s firmware will be restarted, including the configuration
program, and the telnet/SSH session with the unit will end. At this point, the new firmware will be
running, and logging into the TRip2 and checking the version number will confirm this. From TRip2
version 2.2.0 onwards, there is no longer any need to reboot the unit after it has been updated.
If access to the internet is not available, the update file can be downloaded to a local server for local
downloading. In this case, note that both the update file and the accompanying .md5 file must be
downloaded, and the .md5 file must be made available in the same directory as the update file.
Note that the %h, %i and %m macros available in the original TRip are deprecated, and not used in
the TRip2.
4.7. Configuration Access Security
Access to the local or remote command-line interface (see section 4.8) is controlled using a
configurable access name and access password combination.
Each time a new SSH/telnet session is connected to the unit, the access name and password must be
entered prior to any configuration commands.
When the units leave the factory the access name is set to “default” and no password is required.
4.8. Alarms
The TRip2 will maintain a number of internal alarm status variables. These variables will be set or
unset based upon operating conditions encountered by the unit. Each alarm variable (except for the
LAN alarm) will have an associated local and remote delay parameter. These delays will be used to
minimise false alarm signalling to local or remotely based alarm monitoring systems. If an alarm
status variable is unset during the delay period, no alarm condition is signalled. A delay setting of 0
disables the alarm.